The inverter is a direct current energy (battery, battery) into alternating current (typically 220 volts 50HZ sine wave or square wave) devices. The most common emergency power, usually the bottle is inverted into 220V DC communication. Simply put, the 4000w solar inverter is a kind of direct current into alternating current devices.
Whether in remote villages or the wild need or emergency power, the inverter is a very good choice. More common is the engine room of the UPS power will be used, when a sudden power failure, UPS can reverse into a DC battery Reid exchange for computer use, to prevent data due to sudden power loss caused problems. Able to provide uninterrupted power supply, it has a certain security and reliability, stability. The 1000w charger inverter can also be supporting the use of the generator can effectively save fuel, reduce noise, wind energy, solar energy, the inverter is essential. The Pure sine wave power inverter can also use small cars, boats, portable AC power supply equipment in the field.
Due to the diversity of architecture, is bound to lead to the diversity of solar panel installation, in order to make the solar energy conversion efficiency is the highest while taking into account the architectural appearance, which requires the diversify our 8000 watt power inverters, the best way to accomplish the conversion of solar energy.
2015年5月25日星期一
2015年4月26日星期日
12v power inverter
Two products in high demand — the 8000 and 12 volt power inverters by AIMS Power — have been rethought to meet industry needs with a more compact, user-friendly design.
The body of AIMS Power’s new 8000w home inverter is half the weight of the old, 21 pounds as opposed to 42, and its frame is also half the size, which makes it applicable to a more diverse range of jobs.
The new 10000 watt inverter is also two times lighter and smaller than any other inverter in its class available for sale online or in stores today.
“We sold a lot of the old models, but they were so big that our customers would basically have to create another compartment outside their power room in order to make it fit,” manager of power inverter, Michael Shepherd said. “We will no longer carry the old version because this one is just better in every way for our customers.”
Other upgrades include: 1, a redesign of the inverters’ ac outlets, which were converted from a cluster to a strip layout to improve functionality when using abnormally shaped plugs; 2, an improved terminal block, which ensures that the inverters put out the max power promised (8000 and 10000 watts); 3, DC inputs that are simplified to one positive and negative, rather than four of each, making for an easier install; and 4, a single fan system, as opposed to a dual, which makes the inverters much more quiet during use and still performs the cooling duty just as well.
Another big advantage to these high powered inverters is the capability to run them off of most vehicles’ standard power systems at 12 volts. This is uncommon amongst inverters with wattage capacities above 8000, making these inverters attractive to mobile business owners or businesses that need reliable mobile power where it otherwise wouldn’t be available.
2015年4月22日星期三
8000 watt power inverters
3000 4000 5000 6000 8000 watt power inverters
Features:
1.Professional solution for Off-Grid solar system
2.Auto switch 5 FUN:3000 watt power inverters
DC to AC, AC bypass, AC charger, solar charger and UPS
3.MPPT Solar Charger. Max solar panel power:3120W
4.DIP Switches: Low Battery, AC Input Range, Power Saver,
O/P Frequency, Solar/Utility AC Priority
5.Efficiencyup 3~5% than SPT, Idle consumptiondown 30~50% 4000w power inverter
6.Output AVR: stabilized AC voltage RMS( optional)
7.Start Auto restart while AC is recovering (optional)
8.Dry contact: alarm signal to start AC backup( optional)
9.RTS: 8000 watt power inverters Measure battery temp. to make temp. compensation
2015年4月18日星期六
Power inverter
5000watt inverter with 15ampere chager
LCD indicator showing the output wattage and the battery voltage
24vdc-220vac 5000 watt power inverters
Full self-protection
| Continuous Power(W): | 500 watt power inverter |
| Wave Form: : | modified sine wave |
| Operating Voltage: | (21v±0.6v)-(31±0.6v) |
| Rated Input Voltage(DC): | 25.6v-26.4v |
| Rated Output Voltage(AC): | 210-230 |
| Output Frequency: | 48-52 |
| Conversion Efficiency: | 85% |
| Static Current(On Rated Valtage Condition): | 0.5A |
| Low Input Voltage Warning: | 20.4v-21.6v |
| Low Input Voltage Shut Off: | 18.4v-19.6v |
| Over Input Voltage Shut Off: | 30v-33v |
| Automatic Recover Voltage: | 23.4v-25.6v |
| Over Temperature Protection: | 60-70 |
| Over Load Protection: | 5000w |
| AC Short Circuit Protection: | yes&(not damage the circuit) |
| DC Reverse Polatity Protection | yes&(need new fuse altering) |
| Working Temperature: | 0-40 |
| Housing Color: | Black |
| AC Receptacle/Outlet/Socket: | Universal/South africa |
| Packing Dimension(cm): | 49*40*40 |
| Gross Weight(kg): | 15 |
2015年3月9日星期一
3000 watt power inverters How to choose the correct ups power inverter mainly pay attention to the following points.
1, the rated output voltage: within a predetermined fluctuation range of the input DC voltage is allowed, it means that the rated voltage of the inverter should be output. Off grid inverter The stability of rated output voltage accuracy is generally defined as follows: In steady-state operation, the voltage fluctuation range should be a limit, such as the deviation does not exceed the rating of ± 3% or ± 5%. Under load mutations or other interfering factors affecting the dynamics of the output voltage deviation should not exceed the rating of ± 8% or ± 10%.
2, the output voltage imbalance: Under normal operating conditions, the inverter output phase voltage unbalance (reverse component of the ratio of positive sequence component) should not exceed a specified value, usually expressed in% as 5 % or 8%.
3, the output voltage waveform distortion: battery power inverter When the inverter output voltage is sinusoidal, shall specify the maximum allowable waveform distortion (or harmonic content). Usually to a total distortion of the output voltage waveform that its value should not exceed 5% (10% single phase output enable).
4, rated output frequency of the inverter output AC voltage frequency should be a relatively stable value, usually frequency 50Hz. Under normal operating conditions the deviation should be within ± 1%.
5, the load power factor: the ability to characterize the capacitive load inverter with inductive load or. vehicle power inverters In the sine condition, the load power factor of 0.7 to 0.9 (hysteresis), the rating is 0.9.
2015年3月6日星期五
4000 watt power inverters Power converters Introduction
Power converters are generic, that is, strip, also called strip, flapper, patch panels, etc. in Hong Kong called the drag strip. Pick up behind the patch panel in addition to our usual DC AC power inverters printed using a power converter product names, and some electrical parameters, such as maximum voltage, maximum current, and frequency. We have to follow these parameters to be used when using power converters, improper use of words, especially the use of inferior power converter when an electric shock, fire and other unsafe incidents. Early domestic power converters are state-owned enterprises in the production and promotion of the market economy, private enterprises have begun to enter Off grid inverter into the power converter industry to make power converter industry has contending scene.
2015年3月3日星期二
5000 watt power inverters Israeli standards
Israel Israel is mainly used in power converters regions, similar to the slope of the line of fire with the zero line of the flat head, the ground is flat head type, standard 5000w pure sine wave inverter electrical parameters inside Israel is the most special, voltage 220V, frequency 50Hz ' ;
8. Australia, China Standard
Australia and China have the same type of socket, three flat head type, voltage 220V, frequency 50Hz;
9 Swiss standards
Swiss three power converters hole almost a straight line parallel to the type, voltage 230V, frequency 50Hz;
10 Danish Standard
Danish standard power converters used in the Nordic inverter bypass switch countries, with the zero line of FireWire hole, square hole in the ground is the type, voltage 230V, frequency 50Hz;
11 Italian standards
Italian power converters are parallel three hole type, voltage 230V, frequency 50Hz; Chinese New GB Power Converters (10)
12 South Africa Standard
South Africa's power converter with FireWire zero DC AC power inverters line and the ground for the type of hole square hole, voltage 220V/230V, frequency of 50Hz.
订阅:
博文 (Atom)